Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Case Rep Med ; 2016: 3601395, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27366151

RESUMO

Craniopharyngioma treatment remains a challenge for clinicians and patients. There are many treatment alternatives; however one of them (intracavitary irradiation) seeks to control this type of benign brain tumor using minimally invasive techniques, with the specific aim of avoiding causing significant damage to important structures surrounding the sellar/suprasellar region. We present the case of a 3-year-old patient with a predominantly cystic craniopharyngioma who underwent intracavitary irradiation by stereotactic placement. Using this approach, the patient showed a successful response with remission of headaches and hydrocephalus. A reduction in the size of the cyst was achieved, without deterioration of visual fields, with no hormonal supplementation being needed, and with no evidence of focal neurological signs.

3.
Rev. med. nucl. Alasbimn j ; 12(49)July 2010. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-580221

RESUMO

Background: 99Tcm-MAG3 is a non-invasive method for the evaluation of renal transplants, giving information about allograft function and short- and long-term allograft survival. However, few studies have validated this observation. Objetive: To determine the predictive power of different scintigraphic parameters on graft survival at 6 -12 months after renal transplantation. Methods: Between 1996-2007, receptors with varying degrees of kidney dysfunction were studied with 99mTc-MAG3 scintigraphy within 14 days after transplantation. Tubular injury score (TISS) ranging I-VI according to severity and renal extraction index (R20/3) were calculated. Survival analysis and Cox regression were used for analysis. Results: Three-hundred and four renograms were performed in 146 allografts (143 receptors, mean age 38.9 +/- 17 years, 81.5 percent from cadaveric donor). Mean follow-up time was 44 months. There was graft loss (GL) in 32 percent renal trasplants. According to severity range, graft survival at 6 and 12 months was: TISS I-II 85.23 percent and 81.17 percent; TISS III-IV 82.43 percent and 80.56 percent, and TISS V-VI 32 percent and 2.,43 percent respectively. TISS score of V-VI score was an independent predictor for GL (HR = 6.3 CI 95 percent 2.9–13; p<0.0001). R20/3 index was not a good predictor of GL. Conclusions: TISS score was an independent predictor of short- and long-term allograft survival using 99mTc-MAG3 scintigraphy performed early after kidney transplantation in patients with suspected patients renal dysfunction. TISS V-VI had a greater discriminatory power. R20/3 index individually did not present a good prognostic performance.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Feminino , Pré-Escolar , Criança , Pessoa de Meia-Idade , Sobrevivência de Enxerto/fisiologia , Transplante de Rim , Análise de Sobrevida , Complicações Pós-Operatórias , Seguimentos , Fatores de Risco , Fatores de Tempo , Compostos Radiofarmacêuticos , Rejeição de Enxerto , Túbulos Renais/lesões , Valor Preditivo dos Testes
4.
Rev. med. nucl. Alasbimn j ; 12(48)abr. 2010. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-553016

RESUMO

Introducción. En el diagnóstico de enfermedad paratiroidea, persiste la necesidad de contar con un procedimiento eficiente que contribuya a tomar la mejor decisión respecto al manejo del paciente; con este propósito se desarrolló un estudio retrospectivo para evaluar el rendimiento de la gamagrafía con 99mTc-Sestamibi luego de la intervención farmacológica con calcitonina en pacientes con diagnóstico de hiperparatiroidismo primario. Método Se incluyeron pacientes con diagnóstico de hiperparatiroidismo primario que fueron evaluados de forma consecutiva con gamagrafía de paratiroides utilizando el protocolo habitual de 99mTc-Sestamibi en dos fases, y el estudio de 99mTc-Sestamibi-calcitonina, con seguimiento mínimo de 6 meses post gamagrafía. Se calculó la sensibilidad (SENS), especificidad (ESP) y exactitud (EXAC) para cada protocolo, entre otros valores estadísticos. Resultados. Los pacientes que fueron sometidos a gamagrafía basal y post-calcitonina fueron 42, de los cuales 35 tuvieron seguimiento completo: a) Estudio Basal: SENS 65,6 por ciento, ESP 100 por ciento, EXAC 68,5 por ciento. Al diferenciarlos por patologías: para adenoma, SENS 53,8 por ciento, ESP 54,5 por ciento; para hiperplasia, SENS 25 por ciento, ESP 90 por ciento. b) Estudio Post-Calcitonina: SENS 92,3 por ciento, ESP 43,5 por ciento, EXAC 94,3 por ciento. Para adenoma, SENS 92,3 por ciento, ESP 45,5 por ciento; para hiperplasia, SENS 25 por ciento, ESP 77,4 por ciento. Conclusiones. Nuestros resultados utilizando el protocolo con calcitonina demuestran aumento de la sensibilidad global, ayuda a clasificar mejor los pacientes con enfermedad paratiroidea e incrementa la exactitud diagnóstica.


Introduction. There is a need to improve the methods for the diagnosis of parathyroid disease allowing to make the most appropriate therapeutic decision. With this purpose, we performed a retrospective study in order to evaluate the diagnostic accuracy of 99mTc-Sestamibi scintigraphy after pharmacologic intervention with calcitonin in patients with primary hyperparathyroidism. Methods. Patients with diagnosis of primary hyperparathyroidism were included, who were consecutively evaluated with parathyroid scintigraphy using the standard double-phase 99mTc-Sestamibi protocol and a study with 99mTc-Sestamibi-calcitonin, having received a follow-up of at least 6 months after the nuclear study. Sensitivity (SENS), specificity (SPE) and accuracy (ACC) were calculated for each protocol, among other statistical parameters. Results. Fourty-two patients were submitted for basal and post-calcitonin scintigraphy, of which 35 had a complete follow-up. a) Basal study: SENS 65,6 percent, SPE 100 percent, ACC 68,5 percent. After classification according to pathology: for adenoma, SENS 53,8 percent, SPE 54,5 percent; for hyperplasia, SENS 25 percent, SPE 90 percent. b) Post-calcitonin study: SENS 92,3 percent, SPE 43,5 percent, ACC 94,3 percent. For adenoma, SENS 92,3 percent, SPE 45,5 percent; for hyperplasia, SENS 25 percent, SPE 77,4 percent. Conclusions Our results using calcitonin protocol demonstrate an increase in global sensitivity, helping to better classify patients with parathyroid disease by improving diagnostic accuracy.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Feminino , Pessoa de Meia-Idade , Adenoma , Calcitonina , Hiperplasia , Neoplasias das Paratireoides , Compostos Radiofarmacêuticos , Adenoma/complicações , Estudos Retrospectivos , Estudos Transversais , Seguimentos , Hiperparatireoidismo Primário , Hiperparatireoidismo Primário/etiologia , Hiperplasia/complicações , Neoplasias da Glândula Tireoide/complicações , Sensibilidade e Especificidade , Valor Preditivo dos Testes
5.
Acta méd. colomb ; 30(2): 45-49, abr.-jun. 2005. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-436689

RESUMO

En la sobrevida del injerto renal intervienen factores identificados desde la evaluación pre trasplante y las variables del posoperatorio temprano con las que se ha logrado establecer opciones de manejo médico que ayudan a mejorar la sobrevida a corto y largo plazo. En este trabajo se incluyen además dos índices gamagráficos como predictores de sobrevida, la escala de injuria tubular TISS (del inglés tubular injury severity scores) y el índice de extracción renal (R20/3). Objetivos: determinar la predicción del TISS y el R20/3 en la sobrevida del injerto a seis meses y un año Sitio: Fundación Clínica Valle del Lili, Cali, Colombia. Diseño estudio observacional analítico de cohorte retrospectiva. Material y métodos: se revisaron las gamagrafías renal 99mTc-Mag3 hechas a los receptores renales en la primera semana postrasplante. Se registraron los índices de TISS y el R20/3. Se revisaron las historias clínicas de estos pacientes obteniendo información demográfica, tiempo de isquemia del órgano, resultados de las biopsias, presencia de rechazo agudo y la evolución de los pacientes. Se realizó análisis estadístico univariado inicial y posteriormente se realizó análisis multivariado y análisis de sobrevida con el programa STATA 5.0...


Assuntos
Transplante de Rim
6.
Rev. med. nucl. Alasbimn j ; 4(14)2002. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-302574

RESUMO

La evaluación de riñones trasplantados se puede realizar por medio de la gamagrafía renal con mercaptoacetiltriglicina (MAG3) marcada con tecnecio 99. Tulchinsky y colaboradores diseñaron la escala de severidad de injuria tubular (TISS) (utilizando MAG3) para evaluar la magnitud del compromiso funcional y determinar la posibilidad de recuperación renal. Objetivo: El presente estudio tuvo por objeto aplicar la escala del TISS a pacientes con diagnóstico de disfunción temprana (primeras 72 horas posterior al transplante) para establecer el pronóstico de recuperación; la capacidad de predicción fue evaluada por seguimiento clínico. Lugar del estudio: Fundación Clínica Valle del Lili, Cali - Colombia Materiales y Métodos: Se evaluaron 20 pacientes con sospecha de disfunción temprana, se aplicó la escala de TISS; se clasificaron en dos grupos: aquellos que recuperaron la función y quienes la perdieron. Se cálculo la concordancia entre observadores al aplicar la escala. Resultados: Los pacientes con disfunción temprana se clasificaron así: TISS 1:4, 2:5, 3:4, 4:3, 5:1 y 6:3. Del grupo total, 14 recuperaron la función y 6 perdieron el trasplante; todos los pacientes con TISS 1 evolucionaron a recuperación de la función y los TISS 6 a pérdida renal. Se encontraron mayores pérdidas en pacientes con escala ü a 4: 85 por ciento vs 16por ciento (p= 0.0012). El grado de acuerdo entre observadores al aplicar la escala de TISS fue 90 por ciento y el estadístico kappa del 0.80. Conclusiones: La importancia de la gamagrafía con MAG3 radica no sólo en la utilidad diagnóstica sino pronóstica; ésta última se puede determinar mediante la aplicación de la escala de TISS, sin embargo se requiere validación con un mayor número de pacientes


Assuntos
Humanos , Complicações Pós-Operatórias , Renografia por Radioisótopo/métodos , Transplante de Rim/efeitos adversos , Acidose Tubular Renal , Tecnécio Tc 99m Mertiatida , Índice de Gravidade de Doença , Previsões
7.
Acta méd. colomb ; 25(2): 89-93, mar.-abr. 2000. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-358436

RESUMO

La evaluación de los riñones trasplantados se puede realizar por medio de la gamagrafía renal con mercaptoacetiltriglicina (MAG3) marcada con tecnecio 99. Tulchinsky y colaboradores diseñaron la escala de severidad de injuria tubular (TISS) (utilizando MAG3) para evaluar la magnitud del compromiso funcional y determinar la posibilidad de recuperación renal. Objetivo: el presente estudio tuvo por objeto aplicar la escala del TISS a pacientes con diagnóstico de disfunción temprana (primeras 72 horas posterior al trasplante) para establecer el pronóstico de recuperación; la capacidad de predicción se evaluó por seguimiento clínico. Lugar del estudio: Fundación Clínica Valle del Lili, Cali - Colombia Material y métodos: se evaluaron 20 pacientes con sospecha de disfunción temprana, se aplicó la escala de TISS; se clasificaron en dos grupos: aquéllos que recuperaron la función y quienes la perdieron. Se cálculo la concordancia entre observadores al aplicar esta escala. Resultados: los pacientes con disfunción temprana se clasificaron así: TISS 1: cuatro, 2: cinco, 3: cuatro, 4: tres, 5: uno y 6: tres. Del grupo total, 14 recuperaron la función y seis perdieron el trasplante; todos los pacientes con TISS 1 evolucionaron a recuperación de la función y los TISS 6 a pérdida renal. Se encontraron mayores pérdidas en pacientes con escala a 4: 85 por ciento vs 16 por ciento (p= 0.0012). El grado de acuerdo entre observadores al aplicar la escala de TISS fue 90 por ciento y el estadístico kappa del 0.80. Conclusiones: la importancia de la gamagrafía con MAG3 radica no sólo en la utilidad diagnóstica sino pronostica; ésta última se puede determinar mediante la aplicación de la escala de TISS, sin embargo se requiere validación con un mayor número de pacientes.


Assuntos
Técnicas de Diagnóstico Urológico/instrumentação , Técnicas de Diagnóstico Urológico/tendências , Técnicas de Diagnóstico Urológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...